Kickout Flashing

1/12/2018

0 Comments

 
Kickout flashing, also known as diverter flashing, is a special type of flashing that diverts rainwater away from the cladding and into the gutter. When installed properly, they provide excellent protection against the penetration of water into the building envelope. 
Several factors can lead to rainwater intrusion, but a missing kickout flashing, in particular, often results in concentrated areas of water accumulation and potentially severe damage to exterior walls. InterNACHI inspectors should make sure that kickouts are present where they are needed and that they are installed correctly. Water penetration into the cladding can occasionally be observed on the exterior wall in the form of vertical water stains, although inspectors should not rely on visual identification. There may be severe damage with little or no visible evidence.
Picture
The kickout was never installed.
  • The need for kickout flashing developed fairly recently and the builder may not have been aware that one was required. The increased amount of insulation and building wrap that is used in modern construction makes buildings less breathable and more likely to sustain water damage. Kickout flashing prevents rainwater from being absorbed into the wall and is more essential than ever.

The following are locations where kickout flashing is critical:
  • anywhere a roof and exterior wall intersect, where the wall continues past the lower roof-edge and gutter. If a kickout flashing is absent in this location, large amounts of water may miss the gutter, penetrate the siding, and become trapped inside the wall; and
  • where gutters terminate at the side of a chimney.
Picture
The kickout was improperly installed.
  • The bottom seam of the flashing must be watertight. If it is not, water will leak through the seam and may penetrate the cladding. 
  • The angle of the diverter should never be less than 110 degrees.
  • The kick-out was modified by the homeowner.
  • Homeowners who do not understand the importance of kickouts may choose to alter them because they are unsightly. A common way this is done is to shorten their height to less than the standard six inches (although some manufacturers permit four inches), which will greatly reduce their effectiveness. Kickout flashings should be the same height as the side wall flashings.
  • Homeowners may also make kickout flashings less conspicuous by cutting them flush with the wall. ​
In summary, kickout flashing should be present and properly installed in order to direct rainwater away from the cladding.
0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    InsideOut Team   

    This blog is to help people better understand their home inspection. It is filled with great in depth advice. If you'd like a topic covered just send us an email on what you need more information on!

    Archives

    November 2020
    October 2020
    March 2020
    November 2018
    April 2018
    March 2018
    February 2018
    January 2018
    December 2017
    November 2017
    October 2017
    September 2017
    July 2017
    May 2017
    April 2017
    March 2017
    February 2017
    January 2017
    April 2014

    Categories

    All
    Appliances
    Home Inspection
    Household Features
    Inspection Reasons

    RSS Feed

    Newsletter Sign Up

Submit

InsideOut
Contact
Information

SE MI: 734.224.0342
N MI:
231-714-6880
OH: 419.215.3856

8314 Whiteford Center Rd
Ottawa Lake, MI 
49267

1354 W Bear Lake Rd NE
Kalkaska, MI
​49646
​
Fax: 
734-224-0241

What We Do

Residential Home Inspections
Commercial Inspections
Radon Testing
Water Quality Testing
Septic/Leach Field Inspections
Sewer Scope Inspections
Well Inspections
Pest Inspections
Structural Inspections
Manufactured Home Certifications
Mold Testing
Infrared Inspections
Home Binder

Social Media

© 2021 InsideoutInspections.net. All Rights Reserved.
  • Home
  • Services
    • Well Inspections
    • Residential Inspection
    • Commercial Inspection
    • Infared/Thermal Imaging
    • Radon Testing
    • Mold Inspections
    • Septic Inspections
    • Pest Inspections
    • Water Quality Testing
    • Structural Inspections
    • Sewer Scope
    • Manufactured Home Certs
    • Home Binder
  • Areas Served
  • Schedule
  • Reviews
  • Contact
  • Blog